Elgar CW-M Series
4.3.5 Setup for Three-Phase Configuration
4.4 Setting the Phase Angle
For multiphase operation, set switches 9 through 12 for the desired phase angle as
specified in the table below.
Lagging Phase Angle Switch 9 Switch 10 Switch 11 Switch 12
“A” 0º ON ON ON ON
330º ON OFF ON ON
315º OFF ON ON ON
300º OFF OFF ON ON
270º ON ON ON OFF
“C” 240º ON OFF ON OFF
225º OFF ON ON OFF
210º OFF OFF ON OFF
180º ON ON OFF ON
150º ON OFF OFF ON
135º OFF ON OFF ON
“B” 120º OFF OFF OFF ON
90º ON ON OFF OFF
60º ON OFF OFF OFF
45º OFF ON OFF OFF
30º OFF OFF OFF OFF
Table 4–2 Phase Angles
31