Elgar CW-M Series
6 MAINTENANCE
6.1 Periodic Service
No routine maintenance on the CW Series unit is required, aside from periodic cleaning.
Once a unit is removed from service, it may be cleaned with isopropyl alcohol (or an
equivalent solvent) on the metal surfaces, and a weak solution of soap and water on the
front panel.
Low pressure compressed air may be used to remove dust from in and around
components on the printed circuit boards.
6.2 Fuse Replacement
Replacement fuses for the CW Series supply are listed below in Table 6–1.
Ref. Designator Location Rating Manufacturer Mfr. P/N Elgar P/N
F1, F2 Motherboard 25A, 250V, T Bussmann MDA-V-25 858-325-25
F3 Motherboard 1A, 250V, T
Bussmann
Littelfuse
C515-1A
230-001S
858-250-11
858-250-11
F4 (CW 801-M,
CW 1251-M)
Motherboard 10A, 500V DC
Littelfuse
KLKD10 858-601-10
F4
(CW 2501-M)
Motherboard 15A, 500V DC
Littelfuse
KLKD15 858-601-15
Table 6–1 Replacement Fuses
CAUTION! Fuse replacement should be performed by
qualified service personnel only. Breaking the quality seal will
invalidate the warranty.