Operation Manual 0-1 SECTION 0 INTRODUCTION Elgar's ContinuousWave™ (CW) Series power sources deliver 800 VA or 1250 VA in a 2U high (3.5 inche
Introduction Elgar CW-P Series 0-2 Operation Manual • 1 phase 45 to 500 Hz AC output; 45-1000 Hz with H–Option. Units may be connected in multipha
Operation Manual 1-1 SECTION 1 SPECIFICATIONS 1.1 Output POWER CW 801P 800 VA CW 1251P 1250 VA CW 2501P 2500 VA Power Factor of Load 0 lag to
Specifications Elgar CW-P Series 1-2 Operation Manual Total Harmonic Distortion 0.65% maximum up to 60 Hz; add 0.05%/10 Hz from 60 Hz to 100 Hz; a
Elgar CW-P Series Specifications Operation Manual 1-3 PHASE Range -359 to +359 degrees Positive phase indicates time lag from reference Accuracy
Specifications Elgar CW-P Series 1-4 Operation Manual PEAK INRUSH CURRENT* (Available in Remote Mode only) Range CW 801P 0 to 25A CW 1251P 0
Elgar CW-P Series Specifications Operation Manual 1-5 POWER FACTOR* Range 0 to 1 Accuracy ±4% of range for linear loads, typical; at >10% of p
Specifications Elgar CW-P Series 1-6 Operation Manual 1.4 Protection Overcurrent: Shutdown mode Accuracy: +/- 1% of full scale, for linear loads w
Elgar CW-P Series Specifications Operation Manual 1-7 SHIPPING WEIGHT CW 801P: 55.25 lbs. (25 kg) CW 1251P: 60.25 lbs. (27 kg) CW 2501P: 93.25
Specifications Elgar CW-P Series 1-8 Operation Manual This page intentionally left blank.
Operation Manual 2-1 SECTION 2 INSTALLATION The Elgar CW series power supply has been fully calibrated and tested prior to shipment. The instrument
Installation Elgar CW-P Series 2-2 Operation Manual 2.2 Wire Gauge Selection The following guidelines assist in determining the optimum cable speci
Elgar CW-P Series Installation Operation Manual 2-3 The following notes apply to Table 3–1 and to the power cable definition: 1. The above figures
Installation Elgar CW-P Series 2-4 Operation Manual 4. Derate the above wire gauge (use a heavier gauge) for higher environmental temperatures sinc
Elgar CW-P Series Installation Operation Manual 2-5 2.3 Mounting Instructions Refer to Figure 3–1 through Figure 3–4 for mounting dimensions and o
Installation Elgar CW-P Series 2-6 Operation Manual Figure 3–2 Mounting Dimensions, Front and Rear Views (CW 801P, CW 1251P)
Elgar CW-P Series Installation Operation Manual 2-7 Figure 3–3 Mounting Dimensions, Front and Rear Views (CW 2501P)
Installation Elgar CW-P Series 2-8 Operation Manual Figure 3–4 Mounting Dimensions, Top and Side Views (CW 801P and CW 1251P)
Elgar CW-P Series Installation Operation Manual 2-9 Figure 3–5 Mounting Dimensions, Top and Side Views (CW 2501P)
Installation Elgar CW-P Series 2-10 Operation Manual 2.5 Power In Connections Connect input power to the INPUT terminal block on the rear panel as
Elgar CW-P Series Installation Operation Manual 2-11 2.5.2 Split-Phase Supply Connections 120–0–120V 1. Remove the protective cover from the term
Installation Elgar CW-P Series 2-12 Operation Manual 2.6 Power Out Connections 1. Remove the protective cover from the terminal block. 2. A facto
Elgar CW-P Series Installation Operation Manual 2-13 2.7 Sense Connections The CW Series unit can be used with or without remote sense leads conn
Installation Elgar CW-P Series 2-14 Operation Manual To utilize remote sensing at the user's load, follow these steps: 1. Remove the protecti
Elgar CW-P Series Installation Operation Manual 2-15 2.8 Remote Control Signal Remote control allows you to set output voltage, lock to an externa
Installation Elgar CW-P Series 2-16 Operation Manual 2.8.3 Sync Output Pulse • Set direction of Clock to ‘OUT’ (see Section 5.3.9). • Sync can be
Elgar CW-P Series Installation Operation Manual 2-17 6. Power up all CW units simultaneously, and ensure that each unit is reporting its address p
Installation Elgar CW-P Series 2-18 Operation Manual Setup 1–Phase Master/Slave Pair Using Menu System 1. Ensure load wiring is removed from the tw
Elgar CW-P Series Installation Operation Manual 2-19 24. Connect the Elgar cable 890-499-00 between the master “M/S OUT” and the slave “M/S IN” co
Installation Elgar CW-P Series 2-20 Operation Manual 2.9.2 Setup for Three–Phase, Two Units per Phase Figure 3–12 Wiring Diagram for Three Phase,
Elgar CW-P Series Installation Operation Manual 2-21 Setup Six CW Units as 3–Phase Master/Slave Set using Menu System 1. Ensure load wiring is rem
Installation Elgar CW-P Series 2-22 Operation Manual 26. Rotate the right knob until the right display reads “A”. 27. Press the ENTER/SAVE button.
Elgar CW-P Series Installation Operation Manual 2-23 54. On the C slave CW press the ENTER/SAVE button. 55. Rotate the left knob until the left d
Installation Elgar CW-P Series 2-24 Operation Manual This page intentionally left blank.
Operation Manual 3-1 SECTION 3 OPERATION This section details the front panel operations of the CW series power source, including the initializatio
Operation Elgar CW-P Series 3-2 Operation Manual Numeric Display. The large, four-digit display in the VOLTAGE/POWER section is a digital voltmeter
Elgar CW-P Series Operation Operation Manual 3-3 ESCAPE Button. Press this button to exit the Menu function without saving parameter changes. Note
i About AMETEK AMETEK Programmable Power, Inc., a Division of AMETEK, Inc., is a global leader in the design and manufacture of precision, programm
Operation Elgar CW-P Series 3-4 Operation Manual OUTPUT Section This section is used to open and close the output relay. Output terminals are av
Elgar CW-P Series Operation Operation Manual 3-5 Enter the menu system, detailed in Section 5.3, by pressing the ENTER/SAVE button once. After displ
Operation Elgar CW-P Series 3-6 Operation Manual 3.4 Programmed Frequency Steps The allowed frequency delta for programmed frequency steps is a fun
Operation Manual 4-1 SECTION 4 PROGRAMMING 4.1 Programming the CW Via the Front Panel Press the PROGRAM button in the VOLTAGE/POWER section to ent
Programming Elgar CW-P Series 4-2 Operation Manual 4.1.1 VOLTAGE/POWER Section To change the voltage range from High to Low or vice-versa, press th
Elgar CW-P Series Programming Operation Manual 4-3 When the left MEASURE and the WATTS LEDs are illuminated, the wattage being sourced at the output
Programming Elgar CW-P Series 4-4 Operation Manual 4.3 Menu Operations There are two buttons in the Menu section of the front panel, ENTER/SAVE and
Elgar CW-P Series Programming Operation Manual 4-5 The Menu LED is used to indicate if changes have been introduced into the menu system. If there h
Programming Elgar CW-P Series 4-6 Operation Manual 4.3.3 Specify Current Limit Type This menu item specifies whether the CW will shut down after a
Elgar CW-P Series Programming Operation Manual 4-7 4.3.7 Recall Machine Settings This menu item, when saved (not cancelled) by the user, will recal
ii This page intentionally left blank.
Programming Elgar CW-P Series 4-8 Operation Manual 4.3.11 RMS Voltage Loop This entry specifies whether the RMS voltage loop is on or off. When the
Operation Manual 5-1 SECTION 5 MAINTENANCE 5.1 Periodic Service No routine maintenance on the CW Series unit is required, aside from periodic clea
Maintenance Elgar CW-P Series 5-2 Operation Manual This page intentionally left blank.
iii Important Safety Instructions Before applying power to the system, verify that your product is configured properly for your particular applicat
iv Product Family: CW801P, CW1251P, CW2501P, CW801P-H, CW1251P-H, CW2501P-H, CW801P-V, CW1251P-V, CW2501P-V Warranty Period: One Year WARRANTY TERMS
Operation Manual v CONTENTS SECTION 1 INTRODUCTION ................ 0-1 SECTION 2 SPECIFICATIONS ..
Komentáře k této Příručce