Programming Elgar CW-P Series
4-8 Operation Manual
4.3.11 RMS Voltage Loop
This entry specifies whether the RMS voltage loop is on or off. When the voltage loop is
turned on, the RMS output voltage is tightly regulated at the sense point and the output
impedance is compensated for. When the voltage loop is off, the output impedance is
not compensated for.
LOOP OFF/ON
4.3.12 Phase A Offset
This setting specifies the offset of the phase A output zero crossing in relation to the
externally applied phaselockloop signal in degrees.
CLPH 0..360
4.3.13 Phase B Offset
This setting specifies the offset of the phase B waveform in relation to the phase A
waveform in degrees.
PHB 0..360
4.3.14 Phase C Offset
This setting specifies the offset of the phase C waveform in relation to the phase A
waveform in degrees.
PHC 0..360
4.3.15 Slave Channel
Refer to Section 3.9, Master/Slave Configurations, for usage.
CHAN A, B, or C
4.3.16 Slave Address
Refer to Section 3.9, Master/Slave Configurations, for usage.
ADDR 0..5
4.3.17 Slave Configuration
Refer to Section 3.9, Master/Slave Configurations, for usage.
CONF A0A0A0C5